CWC LowFriction® UL Type XHHW-2, Aluminum Conductor, 90°C Dry or Wet, Rated 600 V / 1000 V

APPLICATIONS

CWC LowFriction® UL Type XHHW-2 conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications in accordance with the NEC. The conductor is suitable for use in dry or wet locations at temperatures not to exceed 90°C. The conductor is rated 600 V / 1000 V. Although this product may be installed without the application of pulling lubricant, a good quality pulling lubricant is recommended.

CONSTRUCTION
Conductor:

Annealed compact stranded AA-8000 series Aluminum Conductor Material (ACM).
Insulation:
Low coefficient of friction, abrasion, moisture, and heat resistant colored polyvinyl chloride (PVC).
Covering:
Low coefficient of friction, abrasion, moisture, and heat resistant colored crosslinked polyethylene (XLPE).
Conductor Identification:
Colored XLPE
Voltage Rating:
600 V

TEMPERATURE RATINGS
Dry or Wet  90°C

 
MINIMUM BENDING RADIUS 
Overall Diameter Less than or Equal to 1.000 in
Not Under Tension  4x outer diameter
Under Tension (During Pull)  6x outer diameter
Overall Diameter Greater than 1.000 in
Not Under Tension  5x outer diameter
Under Tension (During Pull)  7.5x out diameter

RATINGS AND MARKINGS

  • Sizes 6 7mÊÓÆµ and larger marked FT2
  • Sizes 6 7mÊÓÆµ and larger in all colors sunlight resistant and marked
  • Sizes 1/0 7mÊÓÆµ and larger marked "FOR CT USE"
  • RoHS Compliant

STANDARDS
These conductors are manufactured and tested to meet or exceed the following standards:

  • ASTM B800 -- 8000 Series Aluminum Alloy Wire for Electrical Purposes —Annealed and Intermediate Tempers
  • ASTM B801 -- Concentric-Lay-Stranded Conductors of 8000 Series
  • Aluminum Alloy for Subsequent Covering or Insulation
  • UL 44 -- Thermoset-Insulated Wires and Cables
  • ICEA S-95-658 / NEMA WC70 -- Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • Federal Specification AA-59544
  • Federal specification JC-30B

LISTINGS AND CERTIFICATIONS
UL listed as Type XHHW-2 -- File E360352

PACKING

  • 250 ft reel
  • 500 ft reel
  • 1000 ft reel
  • Master reel
  • Coil

 

Notes
1. Dimensions and weights are subject to standard manufacturing tolerances and are subject to change without notice.



UPDATED 27 FEB 2025

Unit of Measure

Conductor
Size
(7mÊÓÆµ
or
kcmil)

N/A 3/0

Conductor
Diameter
(in)

N/A 0.423

Insulation
Thickness
(in)

N/A 0.055

Overall
Diameter
(in)

N/A 0.533

AL
Weight
(lb / 1000 ft)

N/A 158

Net
Weight
(lb / 1000 ft)

N/A 196.0