7mÊÓÆµ

Skip to Content
Exit
7mÊÓÆµ
  800.342.7215 Search
Close
  • Products
    • Wire & Cable
      • Grounding, Static & Guy Wire
      • Transmission/T-Line & Distribution Cables
      • Multiplex Cables
      • Low Voltage Cables
      • Medium Voltage Cables
      • Armored Cables
      • Control Cables
      • Fiber Optic Cables
      • Portable Power Cables
    • Power Equipment
    • Poles & Pole Line Hardware
    • Accessories
  • Markets
    • Utility
    • Renewable Energy
    • Battery Energy Storage Systems (BESS)
  • Services
    • Cable Management
    • Cable Engineering & Design
    • Supply Chain
    • Value-Added Services
    • Emergency Response Services
  • Resources
    • Technical Resources & Downloads
    • Quality Process
    • Project Gallery
    • Videos
  • About Us
    • Meet the Team
    • News
    • Events
    • Blog
    • Careers
  • 7mÊÓÆµ
    • Global Locator
    • Quote Request
  • Request a Quote
Search
 
Product Catalog

Contact

7mÊÓÆµ
All Categories > Fiber Optic Cables > Loose Tube Fiber Optic Cable

Loose Tube Fiber Optic Cable


Request Information
    Loose Tube Fiber Optic Cable loose-tube-fiber-optic-cable
  • Loose Tube Fiber Optic Dielectric (Non-Armored)
    LooseDielectric (Non-Armored) border=0 data-filename=Single-Jacket-Non-Armored.jpg loading=lazy src=/ImgSmall/Single-Jacket-Non-Armored.jpg title=Loose Tube Fiber Optic<br>Dielectric (Non-Armored) />

    Loose Tube Fiber Optic Dielectric (Non-Armored)

    (11)

    Applications
    Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried

    Constructions
    Dielectric, Armored, Double Armored

    Fiber Count
    2 to 432 fibers in Color-coded Buffer Tubes

    Fiber Types
    Singlemode / Multimode

    Options
    Gel-Filled Core / Steel Central Member / Copper Pair(s)

    Other versions
    Central / Heavy-Duty / Indoor-Outdoor

    Performance
    ANSI/ICEA, IEC, RUS, Telcordia GR-20

    Mechanical Specifications
    Installation
    [+] Maximum installation load 600 lbf (2670 N)
    [+] Maximum operation load 180 lbf (800 N)
    Temperature Range
    [+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
    [+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
    [+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)


    *Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

  • Loose Tube Fiber Optic Single Jacket Armored
    LooseSingle Jacket Armored border=0 data-filename=Single-Jacket-Single-Armor-Dry.jpg loading=lazy src=/ImgSmall/Single-Jacket-Single-Armor-Dry.jpg title=Loose Tube Fiber Optic<br>Single Jacket Armored />

    Loose Tube Fiber Optic Single Jacket Armored

    (11)

    Applications
    Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried

    Constructions
    Dielectric, Armored, Double Armored

    Fiber Count
    2 to 432 fibers in Color-coded Buffer Tubes

    Fiber Types
    Singlemode / Multimode

    Options
    Gel-Filled Core / Steel Central Member / Copper Pair(s)

    Other versions
    Central / Heavy Duty / Indoor-Outdoor

    Performance
    ANSI/ICEA, IEC, RUS, Telcordia GR-20

    Mechanical Specifications
    Installation
    [+] Maximum installation load 600 lbf (2670 N)
    [+] Maximum operation load 180 lbf (800 N)
    Temperature Range
    [+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
    [+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
    [+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)


    *Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

  • Loose Tube Fiber Optic Double Jacket Armored
    LooseDouble Jacket Armored border=0 data-filename=Double_Jacket_Single_Armor_Optical_Fiber_Cable.jpg loading=lazy src=/ImgSmall/Double_Jacket_Single_Armor_Optical_Fiber_Cable.jpg title=Loose Tube Fiber Optic<br>Double Jacket Armored />

    Loose Tube Fiber Optic Double Jacket Armored

    (11)

    Applications
    Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried

    Constructions
    Dielectric, Armored, Double Armored

    Fiber Count
    2 to 432 fibers in Color-coded Buffer Tubes

    Fiber Types
    Singlemode / Multimode

    Options
    Gel-Filled Core / Steel Central Member / Copper Pair(s)

    Other versions
    Central / Heavy Duty / Indoor-Outdoor

    Performance
    ANSI/ICEA, IEC, RUS, Telcordia GR-20

    Mechanical Specifications
    Installation
    [+] Maximum installation load 600 lbf (2670 N)
    [+] Maximum operation load 180 lbf (800 N)
    Temperature Range
    [+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
    [+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
    [+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)


    *Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

  • Loose Tube Fiber Optic Dielectric Double Jacket (Non-Armored)
    LooseDielectric Double Jacket (Non-Armored) border=0 data-filename=Double-Jacket-No-Armor.jpg loading=lazy src=/ImgSmall/Double-Jacket-No-Armor.jpg title=Loose Tube Fiber Optic<br>Dielectric Double Jacket (Non-Armored) />

    Loose Tube Fiber Optic Dielectric Double Jacket (Non-Armored)

    (11)

    Applications
    Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried

    Constructions
    Dielectric, Armored, Double Armored

    Fiber Count
    2 to 432 fibers in Color-coded Buffer Tubes

    Fiber Types
    Singlemode / Multimode

    Options
    Gel-Filled Core / Steel Central Member / Copper Pair(s)

    Other versions
    Central / Heavy Duty / Indoor-Outdoor

    Performance
    ANSI/ICEA, IEC, RUS, Telcordia GR-20

    Mechanical Specifications
    Installation
    [+] Maximum installation load 600 lbf (2670 N)
    [+] Maximum operation load 180 lbf (800 N)
    Temperature Range
    [+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
    [+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
    [+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)


    *Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

  • Loose Tube Fiber Optic Double Jacket Double Armored
    LooseDouble Jacket Double Armored border=0 data-filename=Double_Jacket_Double_Armor_Optical_Fiber_Cable.jpg loading=lazy src=/ImgSmall/Double_Jacket_Double_Armor_Optical_Fiber_Cable.jpg title=Loose Tube Fiber Optic<br>Double Jacket Double Armored />

    Loose Tube Fiber Optic Double Jacket Double Armored

    (11)

    Applications
    Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried

    Constructions
    Dielectric, Armored, Double Armored

    Fiber Count
    2 to 432 fibers in Color-coded Buffer Tubes

    Fiber Types
    Single-mode / Multi-mode

    Options
    Gel-Filled Core / Steel Central Member / Copper Pair(s)

    Other versions
    Central / Heavy Duty / Indoor-Outdoor

    Performance
    ANSI/ICEA, IEC, RUS, Telcordia GR-20

    Mechanical Specifications
    Installation
    [+] Maximum installation load 600 lbf (2670 N)
    [+] Maximum operation load 180 lbf (800 N)
    Temperature Range
    [+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
    [+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
    [+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)

    *Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

  • Loose Tube Fiber Optic Triple Jacket Double Armored
    LooseTriple Jacket Double Armored border=0 data-filename=LOOSE-TUBE-TRIPLE-JACKET-DOUBLE-ARMOR.png loading=lazy src=/ImgSmall/LOOSE-TUBE-TRIPLE-JACKET-DOUBLE-ARMOR.png title=Loose Tube Fiber Optic<br>Triple Jacket Double Armored />

    Loose Tube Fiber Optic Triple Jacket Double Armored

    (11)

    Applications
    Multi-purpose Outdoor - Aerial Lashed, Duct, Direct Buried

    Constructions
    Dielectric, Armored, Double Armored

    Fiber Count
    2 to 432 fibers in Color-coded Buffer Tubes

    Fiber Types
    Single-mode / Multi-mode

    Options
    Gel-Filled Core / Steel Central Member / Copper Pair(s)

    Other versions
    Central / Heavy Duty / Indoor-Outdoor

    Performance
    ANSI/ICEA, IEC, RUS, Telcordia GR-20

    Mechanical Specifications
    Installation
    [+] Maximum installation load 600 lbf (2670 N)
    [+] Maximum operation load 180 lbf (800 N)
    Temperature Range
    [+] Shipping and Storage -40 ºF to +167 ºF (-40 ºC to +75 ºC)
    [+] Installation -22 ºF to +140 ºF (-30 ºC to +60 ºC)
    [+] Operation -40 ºF to +158 ºF (-40 ºC to +70 ºC)


    *Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

Corporate Headquarters
2980 NE 207th Street | Suite PH
Miami, FL 33180
Toll-Free: 800.342.7215|Phone: 954.455.3050
  • Products
  • About 7mÊÓÆµ
  • Careers
  • Technical Resources
  • Global Locator
  • Commercial T&Cs
  • Privacy Policy
  • Website T&Cs
  • Sitemap
Metal LME Price (USD/lb) Date
Aluminum 1.1824 08/08
Copper 4.3964 08/13
US2622
© 7mÊÓÆµ, All Rights Reserved Site created by and Powered by
width=1
Pop-ups Blocked!

Seems like pop-ups are blocked for this page. Please allow popup to complete download. Click here to {DownloadURL} Download Anyway data-caddownloadplswait=Please wait data-canadianzipcodeformat=Postal code entered is not in the proper format class=nodisplay invisible>