7mÊÓÆµ

Skip to Content
Exit
7mÊÓÆµ
  800.342.7215 Search
Close
  • Products
    • Wire & Cable
      • Grounding, Static & Guy Wire
      • Transmission/T-Line & Distribution Cables
      • Multiplex Cables
      • Low Voltage Cables
      • Medium Voltage Cables
      • Armored Cables
      • Control Cables
      • Fiber Optic Cables
      • Portable Power Cables
    • Power Equipment
    • Poles & Pole Line Hardware
    • Accessories
  • Markets
    • Utility
    • Renewable Energy
    • Battery Energy Storage Systems (BESS)
  • Services
    • Cable Management
    • Cable Engineering & Design
    • Supply Chain
    • Value-Added Services
    • Emergency Response Services
  • Resources
    • Technical Resources & Downloads
    • Quality Process
    • Project Gallery
    • Videos
  • About Us
    • Meet the Team
    • News
    • Events
    • Blog
    • Careers
  • 7mÊÓÆµ
    • Global Locator
    • Quote Request
  • Request a Quote
Search
 
Product Catalog

Contact

7mÊÓÆµ
All Categories > Low Voltage Cables > Low Voltage Cables - United States > TOWERGUARD CCA® UL RHH/RHW-2 2kV > TOWERGUARD CCA® 2kV (UL) RHH or RHW-2 Copper Clad Aluminum Conductor/90°C Wet or Dry For Cable Tray Use - Sunlight Resistant - For Direct Burial U.S. Patent No. 8,618,688

TOWERGUARD CCA® 2kV (UL) RHH or RHW-2 Copper Clad Aluminum Conductor/90°C Wet or Dry For Cable Tray Use - Sunlight Resistant - For Direct Burial U.S. Patent No. 8,618,688


Request Information
    TOWERGUARD CCA® 2kV (UL) RHH or RHW-2 Copper Clad Aluminum Conductor/90°C Wet or Dry For Cable Tray Use - Sunlight Resistant - For Direct Burial U.S. Patent No. 8,618,688 esistant-for-direct-burial-u-s-patent-no-8-618-688
  • TOWERGUARD CCA® 2kV (UL) RHH or RHW-2 Copper Clad Aluminum Conductor/90°C Wet or Dry For Cable Tray Use - Sunlight Resistant - For Direct Burial U.S. Patent No. 8,618,688 Applications

    This cable is intended for fixed installation in wind turbine towers. Good resistance to temperatures, oils, ozone and fire. This cable is intended for use in solar power generation applications to connect the inverter to transformer where high flexibility is required, commonly applied to prefabricated inverter and transformer skids.  Additionally, this cable is appropriate for tight battery applications, as well as superior alternatives to battery cable. TOWERGUARD CCA®  can also be used for secondary voltage resistance welding leads and in power supply applications not exceeding 2000V volts.

    Construction
    Nominal voltage: RHH or RHW-2 2000V UL
    Conductor: The conductor shall be a flexible Copperclad Aluminum (CCA), an electrical conductor that has an outer sleeve of copper metallurgically bonded to a solid aluminum core. The combination of these two metals makes it uniquely suited to many electrical applications where weights to electrical conductivity issues are important. This bimetallic wire is much lighter than copper and only slightly heavier than bare aluminum. The density of CCA is about 35% lighter than copper. CCA conducts like copper for AC frequencies. This product meets or exceeds the minimum requirements set forth in ASTM B 566 04.
    Separator: A suitable tape separator between the conductor and insulation.
    Insulation: Ethylene-propylene rubber (EPR) type EP, meeting UL and ICEA requirements for 90ºC.
    Jacket: A heavy duty, thermosetting CPE in accordance with ICEA S-95-658 NEMA WC70 or optional Low Smoke Zero Halogen jacket LSZH.
    Jacket Color: Black
    Print Legend: TOWERGUARD CCA® (SIZE 7mÊÓÆµ OR KCMIL) CU CLAD AL UL 217923 RHH or RHW-2 2000V SUN RES OIL RES U.S. Patent No. 8,618,688 (SEQUENTIAL FOOTAGE MARKER)

    Specifications

    • ICEA S-95-658 / NEMA WC70
    • UL Standard 44
    • ASTM B 566
    • ASTM B 172
    Product Features
    • 35% less expensive than copper cables with equal ampacity
    • Flexible cable design - TOWERGUARD CCA® can bend to a radius of 6 times the O.D. without impairing the insulation.
    • 90 ºC (dry) 90 ºC (wet)
    • Ozone, sunlight, oil, grease, weather, water, chemical and abrasion resistant jacket
    • Surface printed for easy identification
    • 35% lighter weight and easier to install than copper cables with equal ampacity
    • No scrap value (theft deterrent)
    • Sequential footage markers
    • U.S. Patent No. 8,618,688

    Terminals and Splices
    Testing has been completed using TOWERGUARD CCA® with BURNDY® aluminum HYLUG™ terminals and HYLINK™ splices. Both are UL Listed for use on copper clad aluminum cable. 




    *Ampacity is calculated based on ambient air temperature of 30ºC, per 2008 NEC, Table 310-17
    **Ampacity is calculated based on ambient air temperature of 30ºC, not more than three current-carrying conductors in raceway, cable, or earth, per 2008 NEC, Table 310-16

    † Actual shipping weight may vary.

    <bTowerGuard CCA®</b> 2kV border=0 data-filename=TOWERGUARD.jpg loading=lazy src=/ImgSmall/TOWERGUARD.jpg title=<b>TowerGuard CCA®</b> 2kV />

    TOWERGUARD CCA® 2kV (UL) RHH or RHW-2 Copper Clad Aluminum Conductor/90°C Wet or Dry For Cable Tray Use - Sunlight Resistant - For Direct Burial U.S. Patent No. 8,618,688

    (15)
Corporate Headquarters
2980 NE 207th Street | Suite PH
Miami, FL 33180
Toll-Free: 800.342.7215|Phone: 954.455.3050
  • Products
  • About 7mÊÓÆµ
  • Careers
  • Technical Resources
  • Global Locator
  • Commercial T&Cs
  • Privacy Policy
  • Website T&Cs
  • Sitemap
Metal LME Price (USD/lb) Date
Aluminum 1.1824 08/08
Copper 4.3964 08/13
US2622
© 7mÊÓÆµ, All Rights Reserved Site created by and Powered by
width=1
Pop-ups Blocked!

Seems like pop-ups are blocked for this page. Please allow popup to complete download. Click here to {DownloadURL} Download Anyway data-caddownloadplswait=Please wait data-canadianzipcodeformat=Postal code entered is not in the proper format class=nodisplay invisible>