Applications
Directly buried or installed in ducts for 600 volt secondary distribution.

Construction
Concentric stranded or compressed (8176-H24) aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Three phase and one neutral conductor cabled together (LH lay) or parallel if so specified. Black neutrals may be specified is desired.

Standards
Secondary URD quadruplex conductor 600V cable meets or exceeds the following ASTM specifications.
  • B-800 8000 Series Aluminum Alloy Wire for Electrical Purposes
  • B-801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation.
  • B-901 Compressed round stranded Aluminum Conductors using single input wire construction.
  • Secondary UD triplex conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692.
  • UL Standard 44 for Type RHH or RHW-2
  • UL standard 854 for Type USE-2.
.Options
  • Cable in Duct (CIC)
  • Abrasion Resistant
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
QuadruplexAluminum Conductor border=0 data-filename=QUADRUPLEX-URD.jpg loading=lazy src=/ImgMedium/QUADRUPLEX-URD.jpg title=Quadruplex Conductor Type URD Cable<br>Aluminum Conductor />
Unit of Measure
Items QuadruplexAluminum Conductor border=0 data-filename=QUADRUPLEX-URD.jpg loading=lazy src=/ImgSmall/QUADRUPLEX-URD.jpg title=Quadruplex Conductor Type URD Cable<br>Aluminum Conductor />
Tulsa
Quadruplex Conductor 600V Secondary Type URD Cable Aluminum Conductor
QuadruplexAluminum Conductor border=0 data-filename=QUADRUPLEX-URD.jpg loading=lazy src=/ImgSmall/QUADRUPLEX-URD.jpg title=Quadruplex Conductor Type URD Cable<br>Aluminum Conductor />
Dyke
Quadruplex Conductor 600V Secondary Type URD Cable Aluminum Conductor
QuadruplexAluminum Conductor border=0 data-filename=QUADRUPLEX-URD.jpg loading=lazy src=/ImgSmall/QUADRUPLEX-URD.jpg title=Quadruplex Conductor Type URD Cable<br>Aluminum Conductor />
Wittenberg
Quadruplex Conductor 600V Secondary Type URD Cable Aluminum Conductor
QuadruplexAluminum Conductor border=0 data-filename=QUADRUPLEX-URD.jpg loading=lazy src=/ImgSmall/QUADRUPLEX-URD.jpg title=Quadruplex Conductor Type URD Cable<br>Aluminum Conductor />
Notre Dame
Quadruplex Conductor 600V Secondary Type URD Cable Aluminum Conductor
QuadruplexAluminum Conductor border=0 data-filename=QUADRUPLEX-URD.jpg loading=lazy src=/ImgSmall/QUADRUPLEX-URD.jpg title=Quadruplex Conductor Type URD Cable<br>Aluminum Conductor />
Purdue
Quadruplex Conductor 600V Secondary Type URD Cable Aluminum Conductor
Phase
Conductor
Size/7m视频
N/A 4 N/A 2 N/A 2 N/A 1/0 N/A 1/0
Phase
Conductor
Stranding
N/A 7 N/A 7 N/A 7 N/A 19 N/A 19
Phase
Conductor
Insulation
Thickness
N/A 60 mls N/A 60 mls N/A 60 mls N/A 80 mls N/A 80 mls
Neutral Size 7m视频 N/A 4 N/A 4 N/A 2 N/A 2 N/A 1/0
Neutral Stranding N/A 7 N/A 7 N/A 7 N/A 7 N/A 19
Neutral Insulation Thickness N/A 60 mls N/A 60 mls N/A 60 mls N/A 60 mls N/A 80 mls
Single
Phase
Conductor
N/A .345 Inches N/A .403 Inches N/A .403 Inches N/A .522 Inches N/A .522 Inches
Outside
Diameter
N/A .833 Inches N/A .938 Inches N/A .973 Inches N/A 1.188 Inches N/A 1.260 Inches
Weight
(lb/1000 ft)
N/A 258 Lbs N/A 346 Lbs N/A 375 Lbs N/A 541 Lbs N/A 596 Lbs
Ampacity
Direct Burial
N/A 119 Amps N/A 153 Amps N/A 153 Amps N/A 198 Amps N/A 198 Amps
Ampacity
In Duct
N/A 85 Amps N/A 115 Amps N/A 115 Amps N/A 150 Amps N/A 150 Amps